[table id=5 /]
Hip Arthrogram
Indications
- Tear
- Pain
- Trauma
Preparation/Positioning
Positioning: Supine Feet First
Centering: Center on hip
Coil: Body Surface Coil
*Earplugs Mandatory*
Procedure: Moblize area of interest
Dietary Prep: None
Sagittal T1 Fat Sat
FOV
180mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
0.5mm
Coronal T1 Fat Sat FSE
FOV
180mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
0.5mm
Coronal T1 FSE
FOV
180mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
0.5mm
Axial T2 Fat Sat FSE
FOV
180mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
0.5mm
Axial T1 Fat Sat FSE
FOV
180mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
0.5mm
Axial T1 Oblique Fat Sat FSE
FOV
180mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
0.5mm
Plotting:
Angle Parallel to Femoral Neck
Considerations:
- Set phase R-L and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
Plotting:
Angle Orthogonal
Considerations:
- Set phase H-F and compensate for aliasing.
- Open RectFOV above 100% to increase coverage.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
Plotting:
Angle Orthogonal
Considerations:
- Set phase H-F and compensate for aliasing.
- Open RectFOV above 100% to increase coverage.
- Saturation band inferior and superior to our FOV can help reduce artifacts.