[table id=3 /]
Liver
Indications
- Abnormal liver enzymes
- Mass
- Lesion
- Cirrosis
- Hepatitis
- Trauma
Preparation/Positioning
Positioning: Supine
Centering: Over Liver
Coil: Body Surface Coil
*Earplugs Mandatory*
Procedure: Image around breath holds
Dietary Prep: None
Coronal T2 (Single Shot FSE)
FOV
330mm
Image Matrix
320×320
Slice Thickness
6mm
Slice Gap
1mm
Axial T2 Fat Sat (Single Shot FSE)
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial T1 (FLASH/SPGR)
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial Diffusion
FOV
330mm
Image Matrix
160×160
Slice Thickness
6mm
Slice Gap
1mm
Axial T1 DIXON
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial T1 Fat Sat (20 second)
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial T1 Fat Sat (70 second)
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial T1 Fat Sat (5 minute)
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Coronal T1 Fat Sat
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial T1 Fat Sat (20 minute)
Only for EOVIST
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Plotting:
Cover liver dome to iliac crest.
Considerations:
- Set phase A-P and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Plotting:
Cover entire liver
Considerations:
- Set phase H-F and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Kidney
Indications
- Renal Failure
- Mass
- Lesion
- Cyst
- Pain
- Trauma
Preparation/Positioning
Positioning: Supine
Centering: Over kidney
Coil: Body Surface Coil
*Earplugs Mandatory*
Procedure: Image around breath holds
Dietary Prep: None
Coronal T2 (Single Shot FSE)
FOV
330mm
Image Matrix
320×320
Slice Thickness
4mm
Slice Gap
1mm
Axial T2 Fat Sat (Single Shot FSE)
FOV
330mm
Image Matrix
256×256
Slice Thickness
4mm
Slice Gap
1mm
Axial T1 (FLASH/SPGR)
FOV
330mm
Image Matrix
256×256
Slice Thickness
4mm
Slice Gap
1mm
Axial T1 Fat Sat (FLASH/SPGR)
Whole Abdomen
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial Diffusion
FOV
330mm
Image Matrix
160×160
Slice Thickness
4mm
Slice Gap
1mm
Axial T1 DIXON
FOV
330mm
Image Matrix
256×256
Slice Thickness
4mm
Slice Gap
1mm
Axial T1 Fat Sat (Early Enhancement)
FOV
330mm
Image Matrix
256×256
Slice Thickness
4mm
Slice Gap
1mm
Axial T1 Fat Sat (5 minute)
FOV
330mm
Image Matrix
256×256
Slice Thickness
4mm
Slice Gap
1mm
Axial T1 Fat Sat (FLASH/SPGR)
Whole Abdomen
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Coronal T1 Fat Sat
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Plotting:
Cover the entire kidney.
Considerations:
- Set phase A-P and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Plotting:
Cover entire kidney
Considerations:
- Set phase H-F and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Adrenal Gland
Indications
- Abdominal Pain
- Mass
- Lesion
Preparation/Positioning
Positioning: Supine
Centering: Over kidney
Coil: Body Surface Coil
*Earplugs Mandatory*
Procedure: Image around breath holds
Dietary Prep: None
Coronal T2 (Single Shot FSE)
FOV
330mm
Image Matrix
320×320
Slice Thickness
3mm
Slice Gap
1mm
Axial T2 Fat Sat (Single Shot FSE)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Sagittal T2 Fat Sat (Single Shot FSE)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 (FLASH/SPGR)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (FLASH/SPGR)
Whole Abdomen
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial Diffusion
FOV
330mm
Image Matrix
160×160
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 DIXON
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (20 second)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (70 second)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (5 minute)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (FLASH/SPGR)
Whole Abdomen
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Coronal T1 Fat Sat
FOV
330mm
Image Matrix
256×256
Slice Thickness
4mm
Slice Gap
1mm
Plotting:
Cover diaphram through aortic bifurcation
Considerations:
- Set phase A-P and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Plotting:
Cover abdomen wall to abdomen wall
Considerations:
- Set phase H-F and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Plotting:
Cover abdomen wall to abdomen wall
Considerations:
- Set phase H-F and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Pancreas
Indications
- Abdominal Pain
- Mass
- Lesion
- Pancreatitis
Preparation/Positioning
Positioning: Supine
Centering: Over pancreas
Coil: Body Surface Coil
*Earplugs Mandatory*
Procedure: Image around breath holds
Dietary Prep: None
Coronal T2 (Single Shot FSE)
FOV
330mm
Image Matrix
320×320
Slice Thickness
3mm
Slice Gap
1mm
Axial T2 Fat Sat (Single Shot FSE)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Sagittal T2 Fat Sat (Single Shot FSE)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 (FLASH/SPGR)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (FLASH/SPGR)
Whole Abdomen
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Axial Diffusion
FOV
330mm
Image Matrix
160×160
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 DIXON
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (Early Enhancement)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (5 minute)
FOV
330mm
Image Matrix
256×256
Slice Thickness
3mm
Slice Gap
1mm
Axial T1 Fat Sat (FLASH/SPGR)
Whole Abdomen
FOV
330mm
Image Matrix
256×256
Slice Thickness
6mm
Slice Gap
1mm
Coronal T1 Fat Sat
FOV
330mm
Image Matrix
256×256
Slice Thickness
4mm
Slice Gap
1mm
Plotting:
Cover pancreas
Considerations:
- Set phase A-P and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Plotting:
Cover pancreas
Considerations:
- Set phase H-F and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.
Plotting:
Cover abdomen wall to abdomen wall
Considerations:
- Set phase H-F and compensate for aliasing.
- Saturation band inferior and superior to our FOV can help reduce artifacts.
- Radial k space filling can be used if spin echo sequences are selected.
- To save time, T2 images can be performed post contrast between delay T1 images.